Test Item |
Test Standard |
Result |
|
Artificial Weathering Resistance |
GB/T 1865-2009 |
10000 h, no change in coating film |
|
Solar Reflectance Change after Artificial Weathering |
|
≤5% |
|
6M NaOH Resistance |
GB/T 9274-1988 |
3000 h, no change in coating film |
|
6M HCl Resistance |
GB/T 9274-1988 |
1000 h, no change in coating film |
|
Neutral Salt Spray Corrosion |
GB/T 10125-1997 |
1000 h, no change in coating film |
|
Acidic Salt Spray Corrosion |
GB/T 10125-1997 |
600 h, no change in coating film |
|
Aqua Regia Corrosion Resistance |
GB/T 9274-1988 |
48 h, no change in coating film |
|
High Temperature Resistance |
1100°C |
|
|
Thermal Conductivity |
ASTM C518 |
0.09 W/m·K |
|
Tensile Strength |
|
2500 kPa |
|
Impact Strength |
GB/T 1732-1993 |
80 Kg·cm |
|
VOC Content |
GB/T 34675-2017 |
0 |
|
Bond Strength (Adhesion) |
ASTM-D3359 |
5B |
|
Drying Time |
GB/T 1728-1989 |
Surface Dry 2 h Full Cure 14 h |
|
Coverage |
26–35 m²/L |
|
|
Ice Adhesion Reduction Factor |
1.85 |
|
|
Note: The above data were obtained under laboratory conditions according to national standards. Due to uncontrollable environmental factors during actual use, no warranty is given regarding possible deviations. |
||